Guided Positioning
In this mode the positioning is performed directly via the Cali-OS of the CSC-Tool PRO.
For the guided positioning, however, you need to start the calibration manually with a diagnostic device.
Procedure
- Data elements of vehicle and calibration are selected manually
- The Cali-OS accompanies the customer step by step through the positioning of the CSC-Tool PRO right to the calibration
- Measured values are displayed and stored within the Cali-OS
Advantages
- Guided positioning of the reference panels
- The positioning itself and the steps of the procedure are assisted and do not depend on the diagnostic device used
- The positioning parameters and steps of the procedure are documented in the result protocol
Restrictions
- Vehicle data must be selected manually in the Cali-OS
- No feedback from the ECU possible
- The calibration results are not documented in the result protocol