Starting the User-Controlled Positioning
For functional principle and mode description see section User-Controlled Positioning.
Proceed as follows:
- Start user-controlled positioning

- Select >User-controlled positioning<.
- Select vehicle
- The following options are available for the vehicle selection:
- Add manually:
- Enter all the vehicle data.
- Select >Continue<.
- Previously selected vehicles:
- Select the vehicle directly from the overview or use the search and filter function.
- New selection:
- Option 1: Search and select vehicle through VIN or HSN/TSN.
- Option 2: Select vehicle through Manufacturer > Series > Model.
- Select >Continue<.
- Select calibration type
- Select the sensor.
- Specify the sensor position.
- Select the reason for calibration.
- Confirm with >Continue<.
- Select reference panel
- Select the appropriate reference panel with the check box and proceed with >Continue<.
- Check the required hardware for the selected calibration
- Check if the indicated hardware is complete and ready for operation and confirm with >Continue<.
- Attach wheel clamps & 3D panels
- Position the CSC-Tool PRO in front of the vehicle.
- Attach the wheel clamps and 3D panels and level them (see section Attaching the wheel clamps).
- Select >Continue< if the 3D panels are exactly vertical.
- Register the position three-dimensionally
- Move the vehicle forwards and backwards according to the instructions in the Cali-OS, until the three-dimensional position has been captured.
- Then select >Continue<.
- Confirm safety precautions
- Apply the parking brake and confirm with >Applied<.
- Set reference values
- Enter the values for target position, distance, height, centering and parallelism in the Cali-OS according to manufacturer's specifications.
- Optional:
- Save the reference values as presetting.
- Then confirm with >Continue<.
- Align the CSC-Tool PRO
- Align the CSC-Tool PRO centered and parallel in front of the vehicle.
NOTICE

Position the CSC-Tool PRO in a way that distance, parallelism and centering correspond to the nominal values in the Cali-OS display.
- Operate the left and right brakes with the foot.
- Select >Continue<.
- Then:
- Adjust the height of the monitor with the lower button in the Cali-OS (push button and keep pushed to adjust the height automatically).
- Select >Continue<.
- Perform calibration in the diagnostic device
- The reference panel is automatically indicated on the monitor.
- Perform the calibration step in the diagnostic device.
- Optional:
- Add further calibration steps with >Add calibration step<.
- Select >Continue<.
- Save protocol
- To save the protocol in the Car History, enter the VIN and kilometer/mileage reading and select >Save<.
- You can skip this step if necessary.
- Complete the calibration
- Select >Completed< to complete the procedure.
- The calibration protocol is indicated.
- Optional:
- You can print out the protocol with >Print<:
- Select the protocol content and proceed with >Continue<.
- Enter all the data that shall appear on the protocol printout and confirm with >Continue<.
- or
- Send the protocol with >Send< to the stored e-mail address:
- Select the protocol content and proceed with >Continue<.
- Enter all the data that shall be included in the protocol and confirm with >Send<.